Luminous Long Backup UPS

Being one of the leaders in innovation, design sensibility and sales distribution network, we are offering Power Back Up Solutions and Power Back Up System that includes Power Digital Inverters, Online UPS Systems, Line Interactive UPS Systems, Inverter Batteries (Lead Acid and VRLA).

Features & Protection

  • Micro controller based design 
  • Free Pre-loaded battery management software.
  • SMD Technology for reliable and compact design
  • Battery charging commences even at as low as 120 Volt Mains voltage
  • Auto holiday mode preserves battery charge while you are away from home
  • Intelligent thermal management
  • Visual Indicators: Mains On, UPS On, Switch Status, Smart Charge, Overload/ Short Circuit Trip, Charger Fuse Blown, Battery Low Trip and No Load Shutdown
  • Audio Alarms: Mains Fail, Fuse Fail, Battery Low Pre-alarm, Overload Trip, Battery Low Trip and No Load Shutdown
  • Ensures faster battery charging
  • Advanced battery management, which enhances battery life up to 70%
  • Negligible battery-water loss
  • Intelligent continuous charging profile adjustment
  • Overload with Auto Reset
  • Battery Deep Discharge Protection with Reset Option
  • Ultra-Fast Short Circuit Protection
  • Battery Reverse Polarity Protection
inverter dealers in delhi-ncr

Specifications of LONG BACKUP UPS 600/800/1400VA


Regulated UPS mode
Under Voltage 180 +/- 5 V
Undervoltage Restoration 185 +/- 5 V
Over Voltage 265 +/- 5 V
Over Voltage Restoration 260 +/- 5 V
Unregulated UPS mode
Under Voltage 100 +/- 10 V
Undervoltage Restoration 100 +/- 10 V
Over Voltage 300 +/- 10 V
Over Voltage Restoration 290 +/- 10Vss
Output
Voltage (UPS Mode) 230 V(Nominal)
Voltage (Mains Mode) Same as Input
Frequency (UPS Mode) 50Hz.±2%
Frequency (Mains Mode) Same as Input (45-55 Hz.)
Overload > 110 ‰
Transfer Time (typical a.s) 10ms.
Battery Type 12V/120AH-150AH Lead Acid Type
Number 1
Typical Recharge Time 10-12 Hrs.
Protection Battery Deep Discharge, Reverse Polarity, DC Overvoltage
LED DISPLAY
UPS ON Red
SWITCH ON White
Low Battery Pre-Alarm UPS ON+LOW BATTERY LED BLINKS
Battery Low Red
Mains On Red
Smart Charge Red (Along with Mains On LED)
Overload Red
Short Circuit OVERLOAD BLINKING
No Load Shut Down Red
Battery Charged Mains On LED steady
Charging Fuse Blown Mains On (Continuos) with Smart Charge LED (blinking)
ALARMS Low Battery Pre-Alarm Beeps every 10 seconds
Low Battery Trip Beeps Continuously for 10 seconds
Overload Beeps Continuously for 10 seconds
Mains to UPS Beeps every 2 seconds for 5 times
Short Circuit Beeps Continuously for 10 seconds
No Load Shut Down Beeps Continuously for 10 seconds
Charging Fuse Blown Beeps Continuously for 10 seconds
ENVIRONMENTAL
Operating Temperature 0-45o C (32-113 o F)
Storage Temperature 0-45o C (32-113 o F)
Humidity 0-95 % RH non -condensing